[1] |
Gornet MF, Chan FW, Coleman JC, et al. Biomechanical assessment of a PEEK rod system for semi-rigid fixation of lumbar fusion constructs[J]. J Biomech Eng, 2011, 133(8): 081009. DOI: 10.1115/1.4004862.
|
[2] |
Galbusera F, Bellini CM, Anasetti F, et al. Rigid and flexible spinal stabilization devices: a biomechanical comparison[J]. Med Eng Phys, 2011, 33(4): 490-496. DOI: 10.1016/j.medengphy.2010.11.018.
|
[3] |
Biswas JK, Roy S, Rana M, et al. A comparison of rigid, semi-rigid and flexible spinal stabilization devices: a finite element study[J]. Proc Inst Mech Eng H, 2019, 233(12): 1292-1298. DOI: 10.1177/0954411919880694.
|
[4] |
Fan W, Guo LX, Zhao D. Stress analysis of the implants in transforaminal lumbar interbody fusion under static and vibration loadings: a comparison between pedicle screw fixation system with rigid and flexible rods[J]. J Mater Sci Mater Med, 2019, 30(10): 118. DOI: 10.1007/s10856-019-6320-0.
|
[5] |
Jacobs E, Roth AK, Arts JJ, et al. Reduction of intradiscal pressure by the use of polycarbonate-urethane rods as compared to titanium rods in posterior thoracolumbar spinal fixation[J]. J Mater Sci Mater Med, 2017, 28(10): 148. DOI: 10.1007/s10856-017-5953-0.
|
[6] |
Hsieh YY, Tsuang FY, Kuo YJ, et al. Biomechanical analysis of single-level interbody fusion with different internal fixation rod materials: a finite element analysis[J]. BMC Musculoskelet Disord, 2020, 21(1): 100. DOI: 10.1186/s12891-020-3111-1.
|
[7] |
Nohara H, Kanaya F. Biomechanical study of adjacent intervertebral motion after lumbar spinal fusion and flexible stabilization using polyethylene-terephthalate bands[J]. J Spinal Disord Tech, 2004, 17(3): 215-219. DOI: 10.1097/00024720-200406000-00008.
|
[8] |
Di Silvestre M, Lolli F, Bakaloudis G, et al. Dynamic stabilization for degenerative lumbar scoliosis in elderly patients[J]. Spine, 2010, 35(2): 227-234. DOI: 10.1097/BRS.0b013e3181bd3be6.
|
[9] |
Di Silvestre M, Lolli F, Bakaloudis G. Degenerative lumbar scoliosis in elderly patients: dynamic stabilization without fusion versus posterior instrumented fusion[J]. Spine J, 2014, 14(1): 1-10. DOI: 10.1016/j.spinee.2012.10.023.
|
[10] |
Park H, Zhang HY, Cho BY, et al. Change of lumbar motion after multi-level posterior dynamic stabilization with bioflex system : 1 year follow up[J]. J Korean Neurosurg Soc, 2009, 46(4): 285-291. DOI: 10.3340/jkns.2009.46.4.285.
|
[11] |
Selim A, Mercer S, Tang F. Polyetheretherketone (PEEK) rods for lumbar fusion: a systematic review and meta-analysis[J]. Int J Spine Surg, 2018, 12(2): 190-200. DOI: 10.14444/5027.
|
[12] |
Wang Q, Liu J, Shi Y, et al. Short-term effects of a dynamic neutralization system (Dynesys) for multi-segmental lumbar disc herniation[J]. Eur Spine J, 2016, 25(5): 1409-1416. DOI: 10.1007/s00586-015-4307-1.
|
[13] |
Hu Y, Gu YJ, Xu RM, et al. Short-term clinical observation of the Dynesys neutralization system for the treatment of degenerative disease of the lumbar vertebrae[J]. Orthop Surg, 2011, 3(3): 167-175. DOI: 10.1111/j.1757-7861.2011.00142.x.
|
[14] |
Mandigo CE, Sampath P, Kaiser MG. Posterior dynamic stabilization of the lumbar spine: pedicle based stabilization with the AccuFlex rod system[J]. Neurosurg Focus, 2007, 22(1): E9. DOI: 10.3171/foc. 2007. 22.1.9.
|
[15] |
Mavrogenis AF, Vottis C, Triantafyllopoulos G, et al. PEEK rod systems for the spine[J]. Eur J Orthop Surg Traumatol, 2014, 24(S1): S111-S116. DOI: 10.1007/s00590-014-1421-4.
|
[16] |
Li ZH, Li FN, Yu SZ, et al. Two-year follow-up results of the Isobar TTL Semi-Rigid Rod System for the treatment of lumbar degenerative disease[J]. J Clin Neurosci, 2013, 20(3): 394-399. DOI: 10.1016/j.jocn.2012.02.043.
|
[17] |
Wu JC, Huang WC, Tsai HW, et al. Pedicle screw loosening in dynamic stabilization: incidence, risk, and outcome in 126 patients[J]. Neurosurg Focus, 2011, 31(4): E9. DOI: 10.3171/2011.7.FOCUS11125.
|
[18] |
Gomleksiz C, Sasani M, Oktenoglu T, et al. A short history of posterior dynamic stabilization[J]. Adv Orthop, 2012, 2012: 1-12. DOI: 10.1155/2012/629698.
|
[19] |
Oikonomidis S, Ashqar G, Kaulhausen T, et al. Clinical experiences with a PEEK-based dynamic instrumentation device in lumbar spinal surgery: 2 years and no more[J]. J Orthop Surg Res, 2018, 13(1): 196. DOI: 10.1186/s13018-018-0905-z.
|
[20] |
Putzier M, Hoff E, Tohtz S, et al. Dynamic stabilization adjacent to single-level fusion: Part II. No clinical benefit for asymptomatic, initially degenerated adjacent segments after 6 years follow-up[J]. Eur Spine J, 2010, 19(12): 2181-2189. DOI: 10.1007/s00586-010-1517-4.
|
[21] |
Zhou ZJ, Xia P, Zhao X, et al. Can posterior dynamic stabilization reduce the risk of adjacent segment deterioration[J]? Turkish Neurosurg, 2013, 23(5): 579-589. DOI: 10.5137/1019-5149.JTN.6573-12.1.
|
[22] |
Lee SE, Jahng T, Kim HJ. Facet joint changes after application of lumbar nonfusion dynamic stabilization[J]. Neurosurg Focus, 2016, 40(1): E6. DOI: 10.3171/2015.10.FOCUS15456.
|
[23] |
Kashkoush A, Agarwal N, Paschel E, et al. Evaluation of a hybrid dynamic stabilization and fusion system in the lumbar spine: a 10 year experience[J]. Cureus, 2016, 8(6): e637. DOI: 10.7759/cureus.637.
|
[24] |
Tan MS, Wang HM, Wang YT, et al. Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass[J]. Spine (Phila Pa 1976), 2003, 28(9): 888-895. DOI: 10.1097/01.BRS.00000 58719. 48596.CC.
|
[25] |
林周胜, 黄志平, 陈建庭, 等. 棒直径对椎弓根螺钉固定稳定性和脊柱承载影响的生物力学研究[J]. 实用医学杂志, 2013, 29(1): 1-3. DOI: 10.3969/j.issn.1006-5725.2013.01.001.
|
[26] |
Kim K, Park WM, Kim YH, et al. Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine[J]. Proc Inst Mech Eng H, 2010, 224(3): 477-485. DOI: 10.1243/09544119JEIM611.
|
[27] |
Kim YS, Zhang HY , Moon BJ, et al. Nitinol spring rod dynamic stabilization system and Nitinol memory loops in surgical treatment for lumbar disc disorders: short-term follow up[J]. Neurosurg Focus, 2007, 22(1): E10. PMID: 17608331.
|
[28] |
Heo DH, Cho YJ, Cho SM, et al. Adjacent segment degeneration after lumbar dynamic stabilization using pedicle screws and a nitinol spring rod system with 2-year minimum follow-up[J]. J Spinal Disord Tech, 2012, 25(8): 409-414. DOI: 10.1097/BSD.0b013e318231665d.
|
[29] |
Korovessis P, Papazisis Z, Koureas G, et al. Rigid, semirigid versus dynamic instrumentation for degenerative lumbar spinal stenosis: a correlative radiological and clinical analysis of short-term results[J]. Spine (Phila Pa 1976), 2004, 29(7): 735-742. DOI: 10.1097/01.brs.0000112072.83196.0f.
|
[30] |
Ponnappan RK, Serhan H, Zarda B, et al. Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation[J]. Spine J, 2009, 9(3): 263-267. DOI: 10.1016/j.spinee.2008.08.002.
|
[31] |
Abode-Iyamah K, Kim SB, Grosland N, et al. Spinal motion and intradiscal pressure measurements before and after lumbar spine instrumentation with titanium or PEEK rods[J]. J Clin Neurosci, 2014, 21(4): 651-655. DOI: 10.1016/j.jocn.2013.08.010.
|