[1] |
Menezes A H, Vangilder J C, Graf C J, et al. Craniocervical abnormalities: a comprehensive surgical approach[J]. J Neurosurg,1980,53(4):444-455.
|
[2] |
Goel A. Progressive basilar invagination after transoral odontoidectomy: treatment by atlantoaxial facet distraction and craniovertebral realignment[J]. Spine,2005,30(18):E551-E555.
|
[3] |
张宝成,蔡贤华,黄卫兵,等. 颅底凹陷症的分型及治疗进展[J]. 中国脊柱脊髓杂志,2014(07):660-663.
|
[4] |
Goel A. Treatment of basilar invagination by atlantoaxial joint distraction and direct lateral mass fixation[J]. J Neurosurg Spine,2004,1(3):281-286.
|
[5] |
Chandra P S, Kumar A, Chauhan A, et al. Distraction, compression, and extension reduction of basilar invagination and atlantoaxial dislocation: a novel pilot technique[J]. Neurosurgery,2013,72(6):1040-1053.
|
[6] |
Ma X, Yin Q, Wu Z, et al. C2 Anatomy and Dimensions Relative to Translaminar Screw Placement in an Asian Population[J]. Spine,2010,35(6):704-708.
|
[7] |
蔡贤华,王威,王志华,等. 不同前路内固定方式治疗枢椎椎体横行骨折合并 Hangman 骨折稳定性的有限元分析[J]. 中国脊柱脊髓杂志,2014,24(03):257-260.
|
[8] |
Li S, Ni B, Xie N, et al. Biomechanical evaluation of an atlantoaxial lateral mass fusion cage with C1-C2 pedicle fixation[J]. Spine (Phila Pa 1976),2010,35(14):E624-E632.
|
[9] |
Cai X, Liu Z, Yu Y, et al. Evaluation of biomechanical properties of anterior atlantoaxial transarticular locking plate system using three-dimensional finite element analysis[J]. Eur Spine J,2013,22(12):2686-2694.
|
[10] |
Zhang H, Bai J. Development and validation of a finite element model of the occipito-atlantoaxial complex under physiologic loads[J]. Spine (Phila Pa 1976),2007,32(9):968-974.
|
[11] |
陈金水,倪斌,陈博,等. 寰枢椎脱位三维非线性有限元模型的建立和分析[J]. 中国脊柱脊髓杂志,2010,20(09):749-753.
|
[12] |
王建华,尹庆水,夏虹,等. 颅底凹陷症的分型及其意义[J]. 中国脊柱脊髓杂志, 2011, 21(4):290-294.
|
[13] |
Ni B, Zhou F, Guo Q, et al. Modified technique for C1-2 screw-rod fixation and fusion using autogenous bicortical iliac crest graft[J]. Eur Spine J, 2012, 21(1):156-164.
|
[14] |
Panjabi M, Dvorak J, Crisco J R, et al. Effects of alar ligament transection on upper cervical spine rotation[J]. J Orthop Res, 1991, 9(4): 584-593.
|
[15] |
Panjabi M, Dvorak J, Crisco J R, et al. Flexion, extension, and lateral bending of the upper cervical spine in response to alar ligament transections[J]. J Spinal Disord, 1991, 4(2): 157-167.
|
[16] |
Li-Jun L, Ying-Chao H, Ming-Jie Y, et al. Biomechanical analysis of the longitudinal ligament of upper cervical spine in maintaining atlantoaxial stability[J]. Spinal Cord, 2014, 52(5): 342-347.
|
[17] |
Wright N. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note[J]. J Spinal Disord Tech, 2004, 17(2):158-162.
|
[18] |
Dorward I G, Wright N M. Seven years of experience with C2 translaminar screw fixation: clinical series and review of the literature[J]. Neurosurgery, 2011, 68(6): 1491-1499, 1499.
|
[19] |
Park J S, Cho D C, Sung J K. Feasibility of C2 translaminar screw as an alternative or salvage of C2 pedicle screws in atlantoaxial instability[J]. J Spinal Disord Tech, 2012, 25(5): 254-258.
|
[20] |
Wang M Y. Cervical crossing laminar screws: early clinical results and complications[J]. Neurosurgery, 2007, 61(5 Suppl 2): 311-315, 315-316.
|
[21] |
马向阳,尹庆水,吴增晖,等. 枢椎椎板螺钉固定的解剖可行性研究[J]. 中国脊柱脊髓杂志, 2006, 16(1):48-51.
|
[22] |
Gorek J, Acaroglu E, Berven S, et al. Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation[J]. Spine, 2005, 30(13):1513-1518.
|
[23] |
Elliott R E, Tanweer O, Boah A, et al. Outcome comparison of atlantoaxial fusion with transarticular screws and screw-rod constructs: meta-analysis and review of literature[J]. J Spinal Disord Tech, 2014, 27(1):11-28.
|
[24] |
Daniel R T, Muzumdar A, Ingalhalikar A, et al. Biomechanical Stability of a Posterior-Alone Fixation Technique After Craniovertebral Junction Realignment[J]. World Neurosurg, 2012, 77(2): 357-361.
|
[25] |
Cai X, Yu Y, Liu Z, et al. Three-dimensional finite element analysis of occipitocervical fixation using an anterior occiput-to-axis locking plate system: a pilot study[J]. Spine J, 2014, 14(8):1399-1409.
|
[26] |
Oh C H, Ji G Y, Seo H S, et al. Repeated complication following atlantoaxial fusion: a case report[J]. Korean J Spine, 2014, 11(1):7-11.
|
[27] |
Ordway N R, Lu Y, Zhang X, et al. Correlation of cervical endplate strength with CT measured subchondral bone density[J]. Eur Spine J,2007, 16(12): 2104-2109.
|