[1] Lapner M, King GJ. Radial head fractures [J]. J Bone Joint Surg Am, 2013, 95(12):1136-1143.
[2] Van Glabbeek F, van Riet RP, Morrey BF, et al. The kinematic importance of radial neck length in radial head replacement [J]. Med Eng Phys,2005,27(4):336-342. DOI:10.1016/j.medengphy. 2004. 04.011.
[3] Ricón FJ, Sanchéz P, Guerado E, et al. Result of a pyrocarbon prosthesis after comminuted and unreconstructable radial head fractures [J]. J Shoulder Elbow Surg, 2012,21(1):82-91. DOI:10.1016/j.jse. 2011.01.032.
[4] Rotini R, Marinelli A, Cavaciocchi M, et al. Radial head replacement with unipolar and bipolar SBi system: a clinical and radiographic analysis after a 2-year mean follow-up [J]. Musculoskelet Surg, 2012, 96(Suppl 1): 69-79. DOI:10.1007/s12306-012-0198-z.
[5] Sarris IK, Kyrkos MJ, Kapetanos GA, et al. Radial head replacement with the MoPyC pyrocarbon prosthesis [J]. J Shoulder Elbow Surg, 2012, 21(9):1222-1228. DOI:10.1016/j.jse.2011.12.004.
[6] Burkhart KJ, Mattyasovszky SG, essmann MH, et al. Mid- to long-term results after bipolar radial head arthroplasty [J]. J Shoulder Elbow Surg, 2010, 19(7):965-972. DOI:10.1016/j.jse.2010.05.022.
[7] Gauci MO,Winter M, Allieu Y, et al. Clinical and radiologic outcomes of pyrocarbon radial head prosthesis: midterm results [J]. J Shoulder Elbow Surg, 2016, 25(1): 98-104. DOI:10.1016/j.jse.2015.08.033.
[8] Kodde IF, Heijink A, Eygendaal D, et al. Press-fit bipolar radial head arthroplasty, midterm results [J]. J Shoulder Elbow Surg, 2016, 25(8):1235-1242. DOI:10.1016/j.jse.2016.02.007.
[9] Heijink A, Kodde IF, Eygendaal D, et al. Radial head arthroplasty: a systematic review [J]. JBJS Reviews, 2016, 4(10):e3. DOI:10.2106/JBJS.RVW.15.00095.
[10]Kodde IF, van Rijn J, Eygendaal D, et al. Surgical treatment of post traumatic elbow stiffness: a systematic review [J]. J Shoulder Elbow Surg, 2013, 22(4):574-580. DOI:10.1016/j.jse.2012.11.010.
[11]Van Riet R, Sanchez-Sotelo J, Morrey B. Failure of metal radial head replacement [J]. J Bone Joint Surg Br, 2010, 92(5):661-667. DOI:10.1302/0301-620X.92B5.23067.
[12]Duckworth AD, Wickramasinghe NR, McQueen MM, et al. Radial head replacement for acute complex fractures: what are the rate and risks factors for revision or removal [J]. Clin Orthop Relat Res, 2014, 472(7):2136-2143. DOI:10.1007/s11999-014-3516-y.
[13]Kataoka T, Moritomo H, Sugamoto K, et al. Three-dimensional suitability assessment of three types of osteochondral autograft for ulnar coronoid process reconstruction [J]. J Shoulder Elbow Surg, 2014, 23(2): 143-150. DOI:10.1016/j.jse.2013.10.004.
[14]Bellato E, O'Driscoll SW. Prosthetic replacement for coronoid deficiency: report of three cases [J]. J Shoulder Elbow Surg, 2017, 26(3): 382-388. DOI:10.1016/j.jse.2016.09.039.
[15]Koo TK, Li MY. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research [J]. J Chiropr Med, 2016 ,15(2):155-163. DOI:10.1016/j.jcm.2016.02.012.
[16]Morrey BF, An KN, Stormont T. Force transmission through the radial head [J]. J Bone Joint Surg(Am),1988, 70(2):250-256.
[17]Alolabi B, Studer A, Athwal GS, et al. Selecting the diameter of a radial head implant: an assessment of local landmarks [J]. J Shoulder Elbow Surg, 2013, 22(10):1395-1399. DOI:10.1016/j.jse.2013.04.005.
[18]Giannicola G, Sedati P, Bullitta G, et al. Contribution of cartilage to size and shape of radial head circumference: magnetic resonance imaging analysis of 78 elbows [J]. J Shoulder Elbow Surg, 2006, 25(1):120-126. DOI:10.1016/j.jse.2015.07.003.
[19]Zhang W, Ji Y, Li D, et al. Can the recovery of lower limb fractures be achieved by use of 3D printing mirror model? [J]. Injury, 2017, 48(11): 2485-2495. DOI:10.1016/j.injury.2017.09.003.
[20]Milano G, Saccomanno MF, Magarelli N, et al. Analysis of agreement between computed tomography measurements of glenoid bone defects in anterior shoulder instability with and without comparison with the contralateral shoulder [J]. Am J Sports Med, 2015, 43(12): 2918-2926. DOI:10.1177/0363546515608167.
[21]张飞, 许霖, 张强,等. MRI三维重建评估肩关节脱位关节盂骨缺损的应用研究 [J]. 中国修复重建外科杂志, 2023, 37(5): 551-555. DOI: 10.7507/1002-1892.202301050.
[22]Zhang HL, Lin KJ, Lu Y. Prediction of the Size of the Fragment in Comminuted Coronoid Fracture Using the Contralateral Side: An Analysis of Similarity of Bilateral Ulnar Coronoid Morpholog [J]. Orthopaedic Surgery, 2020,12(5):1495-1502. DOI:10.1111/os.12780.
[23]Giannicola G, Spinello P, Scacchi M, et al. Cartilage thickness of distal humerus and its relationships with bone dimensions: magnetic resonance imaging bilateral study in healthy elbows [J]. J Shoulder Elbow Surg, 2017, 26(5): e128-e136. DOI:10.1016/j.jse.2016.10.012.
[24]李尚哲,杨珖, 鲁谊,等.肱骨远端关节软骨的三维分布及双侧配准研究 [J].中华肩肘外科电子杂志, 2023, 11(4):330-337.DOI:10.3877/cma.j.issn.2095-5790.2023.04.006.
[25]Boileau P, Bicknell RT, Mazzoleni N, et al. CT scan method accurately assesses humeral head retroversion [J]. Clin Orthop Relat Res, 2008, 466(3):661-669. DOI:10.1007/s11999-007-0089-z.
[26]Bryce CD, Pennypacker JL, Kulkarni N, et al. Validation of three-dimensional models of in situ scapulae [J]. J Shoulder Elbow Surg, 2008,17(5):825-832. DOI:10.1016/j.jse.2008.01.141.
|