[1] 安珍,杨定焯,张祖君,等.骨质疏松性脊柱压缩性骨折流行病学调查分析[J]. 中国骨质疏松杂志,2002,8(1):82-83.
[2] Joseph RN, Swift AJ, Maliakal PJ. Single centre prospective study of the efficacy of percutaneous cement augmentation in the treatment of vertebral compression fractures[J].Br J Neurosurg, 2013, 27(4):59-64.
[3] Bouza C, López T, Magro A, et al. Efficacy and safety of balloon kyphoplasty in the treatment of vertebral compression fractures :a systematic review[J]. Eur Spine J, 2006, 15(7):1050-1067.
[4] Chen B, Li Y, Xie D, et al. Comparison of unipedicular and bipedicular kyphoplasty on the stiffness and biomechanical balance of compression fractured vertebrae [J]. Eur Spine J, 2011, 20(8):1272-1280.
[5] Genant HK, Jergas M, Palermo L, et al. Comparison of semiquantitative visual and quantitative morphometric assessment of prevalent and incident vertebral fractures in osteoporosis The Study of Osteoporotic Fractures Research Group[J]. J Bone Miner Res,1996,11(7):984-996.
[6] Balibert P, Deramond H, Rosat P, et al. Pfiliminany note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty[J]. Neurochirurgie, 1987, 33(2):166-168.
[7] 邓忠良,安洪,任广军,等. 经皮穿刺椎体成形术中骨水泥表面温度变化的观察[J]. 中国脊柱脊髓杂志, 2003, 13(2):98-99.
[8] Amar AP, Lmscn DW, Eanaashari N, et al. Perotaneous transpedicular playmethylmethacrylate vertebroplasty for the treatment of spinal complession fractures [J].Neurosurgery, 2001, 49(5):1105-1114.
[9] 罗显禄,郑昌坤,勘武生, 等. 经皮椎体后凸成形单侧与传侧穿刺注入骨水泥治疗骨质疏松性骨折[J]. 中国组织工程研究,2012, 16(3):567-570.
[10]Ryu KS, Park CK, Kim MK,et al. Single balloon kyphoplasty using far-lateral extrapedicular approach : technical note and preliminary results [J]. Spinal Disord Tech, 2007, 20(5):392-398.
[11]王兆红,吴德辉,马超, 等. 双侧经椎弓根入路与单侧经椎弓根外极外侧入路在椎体成形术中的应用比较[J].中国骨伤,2012, 25(12):975-978.
[12]刘绪立,雷伟,郑金, 等. 流体在椎体内流动及分布规律的实验研究[J].中国脊柱脊髓杂志,2006, 16(8):626-629.
[13]郑召民,刘尚礼,李春海,等. 经皮椎体成形术治疗骨质疏松压缩性骨折的临床初步报告[J].中国微创外科杂志, 2001, 6(6):334-335.
[14]Baroud G, Crookshank M, Bohner M. High-viscostiy cement significantly enhances uniformity of cement filling invertebroplasty: an experimental model and study on cement leakage[J].Spine(Phila Pa 1976), 2006, 31(22):2562-2568.
[15]Liebschner MAK, Rosenberg WS, Keaveny TM. Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty [J].Spine, 2001, 26(14):1547-1554.
[16]Tohmeh AG, Mathis JM, Fenton DC, et al. Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures[J].Spine,199,24(17):1772-1776.
[17]Dean IR, Ison KT, Gishen P. The strengthening effect of percutaneous vertebroplasty [J]. Clin Radiol, 2000, 55(6):471-476.
[18]Kim AK, Jensen ME, Dion JE, et al. Unilateral transpedicular percutaneous vertebroplasty: initial experience[J].Radiology, 2002, 222(3):737-741.
[19]Chang WS, Lee SH, Choi WG, et al. Unipedicular vertebroplasty for osteoporatic compression fracture using an individualized needle insertion angle[J]. Clin J Pain, 2007, 23(9):767-773.
[20]Yeom JS, Kim WJ, Choy WS,et al. Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures[J].J Bone Joint Surg(Br), 2003, 85(1):83-89.
[21]Taylor RS, Fritzell P, Taylor RJ. Balloon kyphoplasty in the management of vertebral compression fractures: an updated systematic review and meta-analysis[J]. Eur Spine J, 2007,16(8):1085-1100.
[22]Philips FM. Minimally invasive treatments of osteoporotic vertebral compression fractures[J].Spine, 2003, 27(15 Suppl):45-53.
[23]Figueiredo N, Barra F, Moraes L, et al. Percutaneous vertebroplasty: a comparison between the procedure using the traditional and the new side-opening cannular for osteoporotic vertebral fracture[J]. Arq Neuropsiquiatr, 2009, 67(2B):377-381.
[24]樊仕才,江振华,朱庆安, 等.经皮椎体成形术的实验研究及临床应用[J].中国临床解剖学杂志,2002,20(6):481-483. |