[1] |
Dienstknecht T, Horst K, Pishnamaz M, et al. A meta-analysis of operative versus nonoperative treatment in 463 scapular neck fractures[J]. Scand J Surg, 2013, 102(2): 69-76. DOI: 10.1177/1457496913 482251.
|
[2] |
Coimbra R, Conroy C, Tominaga GT, et al. Causes of scapula fractures differ from other shoulder injuries in occupants seriously injured during motor vehicle crashes[J]. Injury, 2010, 41(2): 151-155. DOI: 10.1016/j.injury.2009.07.006.
|
[3] |
Dr Mayur B Vania. A retrospective analysis of extra articular glenoid neck fracture of scapula (a study of 20 cases)[J]. Int J Orthop Sci, 2019, 5(1): 24-29. DOI: https://doi.org/10.22271/ortho.2019.v5.i1a.05.
|
[4] |
Kannan S, Singh HP, Pandey R. A systematic review of management of scapular fractures[J]. Acta Orthop Belg, 2018, 84(4): 497-508. PMID: 30879456.
|
[5] |
Schroder LK, Gauger EM, Gilbertson JA, et al. Functional outcomes after operative management of extra-articular glenoid neck and scapular body fractures[J]. J Bone Joint Surg Am, 2016, 98(19): 1623-1630. DOI: 10.2106/JBJS.15.01224.
|
[6] |
Cole PA Jr, Gilbertson JA, Cole PA Sr. Functional outcomes of operative management of scapula fractures in a geriatric cohort[J]. J Orthop Trauma,2017, 31(1): e1-e8. DOI: 10.1097/BOT.0000000 000000710.
|
[7] |
Panigrahi R, Madharia D, Das DS, et al. Outcome analysis of intra-articular scapula fracture fixation with distal radius plate: a multicenter prospective study[J]. Arch Trauma Res, 2016, 5(4): e36406. DOI: 10.5812/atr.36406.
|
[8] |
Yuan Z, Zhang F, Liang G, et al. Ring versus non-ring plate for the treatment of displaced scapular body fractures: a retrospective study with a mean follow-up of 5 years[J]. J Int Med Res, 2018, 46(7) 2731-2742. DOI: 10.1177/0300060518770568.
|
[9] |
Hu Y, Shi H, Wang F, et al. Functional outcomes of extra-articular scapula fracture fixation with distal humeral Y-type locking plate: a retrospective study[J]. J Orthop Surg Res, 2019, 14(1): 176. DOI: 10.1186/s13018-019-1205-y.
|
[10] |
Esenkaya İ, Ünay K. Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures[J]. Acta Orthop Traumatol Turc, 2011, 45(3): 156-161. DOI: 10.3944/AOTT.2011.2584.
|
[11] |
余杰锋. 肩胛骨解剖钢板的研制及其有限元力学分析[D]. 广州: 广州医科大学, 2015.
|
[12] |
张彦群, 宋展昭. 肩胛骨颈部骨折解剖钢板的设计制作与临床应用[J]. 中国矫形外科杂志, 2007, 15(6): 404-407, 410. DOI: 10.3969/j.issn.1005-8478.2007.06.002.
|
[13] |
史会明, 胡远军, 陈建华, 等. 新型成人肩胛骨解剖型锁定接骨板的设计研究[J]. 中华创伤骨科杂志, 2018, 20(7): 617-622. DOI: 10.3760/cma.j.issn.1671-7600.2018.07.013.
|
[14] |
Ao R, Yu B, Zhu Y, et al. Single lateral versus medial and lateral plates for treating displaced scapular body fractures: a retrospective comparative study[J]. J Shoulder Elbow Surg, 2018, 27(2): 231-236. DOI: 10.1016/j.jse.2017.07.028.
|
[15] |
杨国义, 杨旭, 杜洋, 等. 双入路双重建钛板内固定治疗不稳定型肩胛颈骨折[J]. 中华创伤骨科杂志, 2013, 15(4): 293-297. DOI: 10.3760/cma.j.issn.1671-7600.2013.04.004.
|
[16] |
Pizanis A, Tosounidis G, Braun C, et al. The posterior two-portal approach for reconstruction of scapula fractures: results of 39 patients[J]. Injury, 2013, 44(11): 1630-1635. DOI: 10.1016/j.injury. 2013. 07. 020.
|
[17] |
李光荣, 林长生, 冷卫国, 等. 斜T型钢板内固定治疗肩胛颈骨折[J]. 中国实用医药, 2011, 6(18): 25-26. DOI: 10.3969/j.issn.1673-7555. 2011. 18.012.
|
[18] |
钱军, 方跃鸣, 张仲华, 等. 联合小切口、微型钢板内固定治疗肩胛骨体部粉碎性骨折[J]. 浙江医学, 2017, 39(13): 1111-1112, 1115. DOI: 10.12056/j.issn.1006-2785.2017.39.13.2016-227.
|
[19] |
刘成文, 张明贵, 曹云, 等. 复杂性粉碎性肩胛骨骨折的手术治疗[J]. 中国矫形外科杂志, 2009, 17(10): 797-798. CNKI: SUN:ZJXS.0.2009-10-035.
|
[20] |
史会明, 王飞, 胡远军, 等. 基于3D模型并肩胛骨接骨板设计的肩胛骨测量[J]. 中国临床解剖学杂志, 2018, 36(4): 387-391. DOI: 10.13418/j.issn.1001-165x.2018.04.007.
|
[21] |
陆继鹏, 赵烽, 杨慧勤, 等. 桥接系统内固定治疗肩胛骨骨折的初步疗效观察[J]. 中国骨与关节损伤杂志, 2018, 33(9): 978-980. DOI: 10.7531/j.issn.1672-9935.2018.09.028.
|
[22] |
Grieshober JA, Palmer JE, Kim H, et al. Comparison of curved and straight anchor insertion for bankart repair[J]. Orthopedics, 2019, 42(2): e242-e246. DOI: 10.3928/01477447-20190125-04.
|
[23] |
Thompson G, Van Den Heever A. Coracoid stress fracture in an elite fast bowler: description of a technique for CT-guided percutaneous screw fixation of coracoid fractures[J]. Skeletal Radiol, 2019, 48(10): 1611-1616. DOI: 10.1007/s00256-019-03184-2.
|
[24] |
陈敏, 白龙, 马灿泽, 等. 异形钢板的研制及其在肩胛骨骨折的应用[J]. 中国骨伤, 2005, 18(11): 658-660. DOI: 10.3969/j.issn.1003-0034.2005.11.008.
|
[25] |
Sulkar HJ, Tashjian RZ, Chalmers PN, et al. Mechanical testing of scapular neck fracture fixation using a synthetic bone model[J]. Clin Biomech (Bristol, Avon), 2019, 61: 64-69. DOI: 10.1016/j.clinbiomech. 2018.11.007.
|
[26] |
Park AY, DiStefano JG, Nguyen TQ, et al. Congruency of scapula locking plates: implications for implant design[J]. Am J Orthop (Belle Mead NJ), 2012, 41(4): E53- E56. PMID: 22530212.
|