Unimproved versus newly-improved four-corner arthrodesis concentrator: a finite element analysis

JI Bao-Chen, TANG Hui, FAN Xin-Yu, ZHANG Mei-Chao, SHU Ti-Liang, LI Chuan, XU Yong-Qing

Chinese Journal of Clinical Anatomy ›› 2012, Vol. 30 ›› Issue (4) : 447-451.

Chinese Journal of Clinical Anatomy ›› 2012, Vol. 30 ›› Issue (4) : 447-451.

Unimproved versus newly-improved four-corner arthrodesis concentrator: a finite element analysis

  • QI Bao-chuang1,TANG hui1,FAN Xin-yu1,ZHANG Mei-chao2, ZHU Yue-liang1, LI Chuan1,XU Yong-qing1
Author information +
History +

Abstract

Objective    To evaluate biomechanical properties of NiTi shape memory alloy four-corner arthrodesis concentrator (NTMA-FCAC) by the method of finite element analysis and provide theoretical basis for it's clinical application.    Methods    With the analysis function of Ansys8.0, the models of NTMA-FCAC were built. Under the same loading condition as the arthrodesis concentrator devices encountering in fatigue test, the models were stricted and loaded. Through structure analysis, the strain/stress distributions, compression and tension stiffness were processed.    Results    The result showed that, in addition to several stress-bearing areas located in the junctional zones between body and arms, the stress distribution of other parts are even. The stiffness of two models was similar. Within the scope of certain the NTMA-FCAC can satisfy wrist functional exercise postoperatively.   Conclusions  The result shows the newly-improved NTMA- FCAC have excellent biomechanical properties. It can meet clinical application.

Key words

 Finite element / Stress / Wrist / Carpal collapse / Four-corner arthrodesis

Cite this article

Download Citations
JI Bao-Chen, TANG Hui, FAN Xin-Yu, ZHANG Mei-Chao, SHU Ti-Liang, LI Chuan, XU Yong-Qing. Unimproved versus newly-improved four-corner arthrodesis concentrator: a finite element analysis[J]. Chinese Journal of Clinical Anatomy. 2012, 30(4): 447-451

References


[1] Vance MC, Hernandez JD, Didonna ML, et al. Complications and outcome of four-corner arthrodesis: circular plate fixation
[J].J hand Surg Am, 2005, 30(6):1122-1127.

[2] Kendall CB, Brown TR, Millon SJ, et al. Results of four-corner arthrodesis using dorsal circular plate fixation
[J].J hand Surg Am, 2005, 30(5):903-907.

[3]  覃励明,徐永清,吴农新,等.镍钛记忆合金腕骨四角融合器的研制及生物力测试
[J].中华手外科杂志, 2006, 22(3) :137-139.

[4]  王国强. 实用工程数值模拟技术及其在Ansys上的实践
[M].西安:西北工业大学出版社,1999: 53-168.

[5]  张美超,黄文华,王柏川,等. 应用有限元方法评价颈前路蝶形钢板的力学性能
[J].第一军医大学学报,2001,21(10):740-742.

[6]  Anderson DD, Daniel TE. A contact-coupled finite element analysis of the radio-carpal joint
[J]. Semin Arthroplasty ,1995, 6(1):30-36.

[7] Roarth CM, Grosland NM. Adaptive meshing technique applied to orthopaedic finite element contact problem
[J].Iowa Orthop J,2004,24:21-29.

[8] Lin CL, Lin YH, Chen AC. Buttressing angle of the double-plating fixation of a distal radius fracture: a finite element study
[J].Med Biol Eng Comput, 2006, 44(88):665-673.

[9]  梁建彬. 镍钛记忆合金在儿童股骨干长螺旋形骨折中应用的观察
[J].中国骨与关节损伤杂志,2007, 22(3):247-248.