Chinese Journal Of Clinical Anatomy ›› 2012, Vol. 30 ›› Issue (4): 404-407.

Previous Articles     Next Articles

The pedicle and iliac screw fixation in treatment of sacroiliac dislocation and fracture: CT tomography study

YANG Yun-ping, CHEN Hong-feng, WANG Fu-ming, JIA Yi, WANG Gang   

  1. Department of Traumatic Orthopaedics, Nanfang Hosipital, Southern Medical University, Guangzhou 510515  China
  • Received:2011-05-20 Online:2012-07-25 Published:2012-07-27

Abstract:

Objective    To investigate the value of digital model on evaluating pedicle screw and iliac screw in treating sacroiliac dislocation and fracture.    Methods    The pelvic CT data from 40 healthy adults were imported into the Mimics 10.0 software for three-dimensional reconstructing of pelvis. The anatomic parameters concerning with inserting angles and the ilium screws at different directions were measured on the virtual pelvis.    Results    The distance between lateral and medial ilium lamella(the maximum diameter of ilium screw)was about(6.00±0.84)mm,or (6.95±0.50)mm. The length of screw inserting was (59.97±7.99)mm,or (106.69±8.74)mm. TSA was (12.48±7.16)° or (43.93±6.09)°,CSA(56.41±6.47)° or (39.25±6.11)°,and SSA(29.91±5.55)° or 19.24±3.78)° at the different inserting direction, respectively.   Conclusions    Digital pelvic model is a valuable tool to guide clinical treatment of sacroiliac dislocation and fracture through pedicle screw and iliac screws.

Key words: Digital orthopedics, Pedicle and iliac screw, Sacroiliac joint, Internal fixation, Mimics10.0

CLC Number: